{"product_id":"miniature-circuit-breaker-mcb-c60h-c-curve","title":"Schneider Miniature circuit breaker MCB - C60H - C curve","description":"\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003c!-- QUICK ANSWER (Featured snippet friendly) --\u003e\n\u003cdiv style=\"background-color: #fcefb9; padding: 15px; border-left: 4px solid #EFC41A; margin: 15px 0; border-radius: 5px;\"\u003e\n\u003ch3 style=\"color: #328616; margin-top: 0;\"\u003eQuick Answer: What is Schneider C60H MCB used for?\u003c\/h3\u003e\n\u003cp style=\"margin: 0; color: #000000; line-height: 1.7;\"\u003e\u003cstrong\u003eSchneider C60H Miniature Circuit Breaker\u003c\/strong\u003e is a \u003cstrong\u003eC-curve MCB\u003c\/strong\u003e, designed for \u003cstrong\u003eprotecting electrical circuits from overload and short circuit\u003c\/strong\u003e in residential and commercial installations with reliable trip characteristics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul style=\"line-height: 1.9;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e C60H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Curve:\u003c\/strong\u003e C curve (5-10x rated current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Residential and commercial circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric - global electrical leader\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- PRODUCT DESCRIPTION --\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSchneider C60H Miniature Circuit Breaker\u003c\/strong\u003e is a C-curve MCB manufactured by Schneider Electric, engineered for protecting electrical circuits from overload and short circuit conditions. The C-curve trip characteristic makes it suitable for general-purpose applications with moderate inrush currents.\u003c\/p\u003e\n\u003cp\u003eIdeal for residential and commercial electrical installations, the C60H MCB offers reliable protection with quality Schneider Electric engineering. The compact design fits standard distribution boards, making it perfect for electrical installations in Bangalore requiring dependable circuit protection.\u003c\/p\u003e\n\u003c!-- TECH SPECS --\u003e\n\u003cdiv style=\"background-color: #fcefb9; padding: 15px; border-left: 4px solid #328616; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003ch4 style=\"color: #000000; margin-top: 0;\"\u003eTechnical Specifications (Quick Reference)\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 10px 0; border: 1px solid #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #efc41a; color: #000000;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); text-align: left; width: 38.5932%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); text-align: left; width: 61.4068%;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 38.5932%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 61.4068%;\"\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 38.5932%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 61.4068%;\"\u003e240V\/415V AC (Standard models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 38.5932%;\"\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 61.4068%;\"\u003eC curve (5-10x rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 38.5932%;\"\u003e\u003cstrong\u003eAvailable Configurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 61.4068%;\"\u003e1P, 2P, 3P, 4P (P stands for Pole, indicating the number of protected circuits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 38.5932%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid rgb(221, 221, 221); width: 61.4068%;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- USE CASES --\u003e\n\u003ch3\u003eKey Safety Features\u003c\/h3\u003e\n\u003cul style=\"line-height: 1.9;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisiSafe (Green Strip): \u003c\/strong\u003eProvides a visible green indicator to ensure the circuit is fully isolated and safe for maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisiTrip (Red Flag): \u003c\/strong\u003eA red indicator appears on the front face to help you instantly identify which breaker has tripped due to a fault, reducing downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Applications\u003c\/h3\u003e\n\u003cul style=\"line-height: 1.9;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Wiring:\u003c\/strong\u003e Protect lighting and power circuits in homes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Circuit protection for offices and retail spaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Purpose Loads:\u003c\/strong\u003e Suitable for resistive and inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistribution Boards:\u003c\/strong\u003e Install in Schneider or compatible distribution boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e Protect circuits from overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection:\u003c\/strong\u003e Rapid disconnection during short circuit faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- INSTALLATION --\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fcefb9; padding: 15px; border-left: 4px solid #026202; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003col style=\"margin-bottom: 0; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelection:\u003c\/strong\u003e Choose MCB rating based on circuit load and cable size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap MCB onto DIN rail in distribution board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect incoming supply to top terminal, outgoing circuit to bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Test MCB operation before energizing circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabeling:\u003c\/strong\u003e Label circuit for easy identification\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003e1) What is a C-curve MCB?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eC-curve MCB trips at 5-10 times the rated current\u003c\/strong\u003e during short circuit conditions. This makes it \u003cstrong\u003esuitable for general-purpose applications\u003c\/strong\u003e with moderate inrush currents like \u003cstrong\u003elighting, power outlets, and most household appliances\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e2) What is the difference between B, C, and D curve MCBs?\u003c\/h3\u003e\n\u003cp\u003eThe curve indicates the current level required for an instantaneous trip:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eB-Curve (3-5x):\u003c\/strong\u003e For resistive loads like heaters and long cable runs. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC-Curve (5-10x):\u003c\/strong\u003e For general residential and commercial use (lighting, PCs, and appliances).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD-Curve (10-20x): \u003c\/strong\u003eFor high-induction loads like large motors and transformers. C-curve is the standard choice for most modern building installations.\u003c\/p\u003e\n\u003ch3\u003e3) How do I select the right MCB rating?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSelect MCB rating based on circuit load and cable size\u003c\/strong\u003e. The MCB rating should be \u003cstrong\u003eequal to or slightly higher than the circuit load\u003c\/strong\u003e but \u003cstrong\u003enot exceed the cable's current-carrying capacity\u003c\/strong\u003e. Consult electrical standards for proper sizing.\u003c\/p\u003e\n\u003ch3\u003e4) Can I use Schneider C60H for residential wiring?\u003c\/h3\u003e\n\u003cp\u003eYes, \u003cstrong\u003eSchneider C60H MCB is excellent for residential wiring\u003c\/strong\u003e. The \u003cstrong\u003eC-curve characteristic is ideal for protecting lighting and power circuits\u003c\/strong\u003e in homes with reliable overload and short circuit protection.\u003c\/p\u003e\n\u003ch3\u003e5) What is the breaking capacity of the Schneider C60H MCB?\u003c\/h3\u003e\n\u003cp\u003eThe \"H\" in the C60H series stands for \u003cstrong\u003eHigh Breaking Capacity,\u003c\/strong\u003e which is typically \u003cstrong\u003e10kA\u003c\/strong\u003e \u003cstrong\u003e(10,000 Amps) at 240V\/415V AC.\u003c\/strong\u003e This means the MCB can safely interrupt a massive fault current of up to 10,000 Amps without being damaged or failing. This high rating makes it a robust choice for both residential and demanding commercial environments where electrical safety is a priority.\u003c\/p\u003e\n\u003ch3\u003e6) How do I install an MCB in a distribution board?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSnap the MCB onto the 35mm DIN rail.\u003c\/strong\u003e Connect the incoming supply and outgoing circuit to the terminals—Schneider C60H units are\u003cstrong\u003e bi-directional,\u003c\/strong\u003e so power can be fed from the top or bottom. Ensure all terminals are \u003cstrong\u003etorqued tightly\u003c\/strong\u003e to prevent overheating.\u003c\/p\u003e\n\u003ch3\u003e7) How do I identify genuine Schneider MCBs?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGenuine Schneider MCBs have clear markings\u003c\/strong\u003e including brand name, series, rating, and specifications. \u003cstrong\u003ePurchase from authorized dealers\u003c\/strong\u003e and check for \u003cstrong\u003eSchneider hologram and packaging\u003c\/strong\u003e to ensure authenticity.\u003c\/p\u003e\n\u003c!-- Why buy from HomeRun section --\u003e\n\u003ch3\u003eWhy Buy from HomeRun?\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fcefb9; border-left: 4px solid #EFC41A; padding: 15px; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003cul style=\"margin: 0; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuthentic Schneider Electric Products:\u003c\/strong\u003e Verified genuine products from authorized distributors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFresh Stock Guarantee:\u003c\/strong\u003e All MCBs within optimal condition for maximum performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBangalore Fulfilment:\u003c\/strong\u003e Quick local availability with express delivery across Bangalore\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- RETURNS --\u003e\n\u003ch2\u003eReturns \u0026amp; Exchange Policy\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\u003cstrong\u003eThis product is non-returnable.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eReplacement available within 24 hours of delivery for:\n\u003cul\u003e\n\u003cli\u003eDamaged or defective product\u003c\/li\u003e\n\u003cli\u003eWrong or missing item\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct cannot be returned once installed or used\u003c\/li\u003e\n\u003cli\u003eRefer to Refund Policy for complete details\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BuildHome","offers":[{"title":"1 Pole \/ 10A","offer_id":61844407615858,"sku":"SCH-MCB-CC-SP-10A","price":173.0,"currency_code":"INR","in_stock":true},{"title":"1 Pole \/ 20A","offer_id":61844407648626,"sku":"SCH-MCB-CC-SP-20A","price":173.0,"currency_code":"INR","in_stock":true},{"title":"1 Pole \/ 25A","offer_id":61844407681394,"sku":"SCH-MCB-CC-SP-25A","price":173.0,"currency_code":"INR","in_stock":true},{"title":"1 Pole \/ 32A","offer_id":61844407714162,"sku":"SCH-MCB-CC-SP-32A","price":173.0,"currency_code":"INR","in_stock":true},{"title":"1 Pole \/ 40A","offer_id":61844407746930,"sku":"SCH-MCB-CC-SP-40A","price":411.0,"currency_code":"INR","in_stock":true},{"title":"1 Pole \/ 63A","offer_id":61844407779698,"sku":"SCH-MCB-CC-SP-63A","price":417.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 10A","offer_id":61844407812466,"sku":"SCH-MCB-CC-DP-10A","price":549.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 20A","offer_id":61844407845234,"sku":"SCH-MCB-CC-DP-20A","price":549.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 25A","offer_id":61844407878002,"sku":"SCH-MCB-CC-DP-25A","price":549.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 32A","offer_id":61844407910770,"sku":"SCH-MCB-CC-DP-32A","price":549.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 40A","offer_id":61844407943538,"sku":"SCH-MCB-CC-DP-40A","price":884.0,"currency_code":"INR","in_stock":true},{"title":"2 Pole \/ 63A","offer_id":61844407976306,"sku":"SCH-MCB-CC-DP-63A","price":891.0,"currency_code":"INR","in_stock":true},{"title":"3 Pole \/ 10A","offer_id":61844408009074,"sku":"SCH-MCB-CC-3P-10A","price":911.0,"currency_code":"INR","in_stock":true},{"title":"3 Pole \/ 20A","offer_id":61844408041842,"sku":"SCH-MCB-CC-3P-20A","price":911.0,"currency_code":"INR","in_stock":true},{"title":"3 Pole \/ 25A","offer_id":61844408074610,"sku":"SCH-MCB-CC-3P-25A","price":911.0,"currency_code":"INR","in_stock":true},{"title":"3 Pole \/ 32A","offer_id":61844408107378,"sku":"SCH-MCB-CC-3P-32A","price":911.0,"currency_code":"INR","in_stock":true},{"title":"3 Pole \/ 40A","offer_id":61844408140146,"sku":"SCH-MCB-CC-3P-40A","price":1387.0,"currency_code":"INR","in_stock":true},{"title":"3 Pole \/ 63A","offer_id":61844408172914,"sku":"SCH-MCB-CC-3P-63A","price":1433.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 10A","offer_id":61844408205682,"sku":"SCH-MCB-CC-4P-10A","price":1227.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 20A","offer_id":61844408238450,"sku":"SCH-MCB-CC-4P-20A","price":1227.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 25A","offer_id":61844408271218,"sku":"SCH-MCB-CC-4P-25A","price":1227.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 32A","offer_id":61844408303986,"sku":"SCH-MCB-CC-4P-32A","price":1227.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 40A","offer_id":61844408336754,"sku":"SCH-MCB-CC-4P-40A","price":1782.0,"currency_code":"INR","in_stock":true},{"title":"4 Pole \/ 63A","offer_id":61844408369522,"sku":"SCH-MCB-CC-4P-63A","price":1856.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/0405\/1058\/files\/1P_10A.webp?v=1778501836","url":"https:\/\/buildhome.shop\/products\/miniature-circuit-breaker-mcb-c60h-c-curve","provider":"Buildhome","version":"1.0","type":"link"}