{"product_id":"ashirvad-flowguard-plus-end-cap","title":"Ashirvad Flowguard Plus End Cap","description":"\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #fcefb9; padding: 15px; border-left: 4px solid #EFC41A; margin: 15px 0; border-radius: 5px;\"\u003e\n\u003ch3 style=\"color: #328616; margin-top: 0;\"\u003eQuick Answer: What is Ashirvad Flowguard Plus End Cap used for?\u003c\/h3\u003e\n\u003cp style=\"margin: 0; color: #000000; line-height: 1.7;\"\u003e\u003cstrong\u003eAshirvad Flowguard Plus End Cap\u003c\/strong\u003e is a \u003cstrong\u003epipe termination fitting for sealing the end of CPVC pipes\u003c\/strong\u003e, designed for \u003cstrong\u003eclosing off unused pipe ends and dead-end branches in hot and cold water systems\u003c\/strong\u003e with permanent solvent weld sealing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul style=\"line-height: 1.9;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e CPVC (Chlorinated Polyvinyl Chloride)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Pipe end termination and sealing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e Up to 93°C (200°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e SDR-11 (PN 15 \/ 15 kg\/cm²)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Socket type (Solvent Weld)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAshirvad Flowguard Plus End Cap\u003c\/strong\u003e provides a permanent, leak-proof seal for terminating CPVC pipe ends. This essential fitting is used to close off unused branches, dead-end lines, or temporary pipe terminations during phased construction. The precision-molded socket design ensures proper pipe insertion depth and optimal solvent cement bonding for a watertight seal that withstands full system pressure.\u003c\/p\u003e\n\u003cp\u003eManufactured from high-grade CPVC compound, this end cap maintains the same temperature and pressure ratings as the pipe system. The smooth exterior finish allows for easy installation in tight spaces, while the durable construction ensures long-term reliability. Essential for system testing, future expansion provisions, and closing off abandoned pipe sections during renovations.\u003c\/p\u003e\n\u003cdiv style=\"background-color: #fcefb9; padding: 15px; border-left: 4px solid #328616; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003ch4 style=\"color: #000000; margin-top: 0;\"\u003eTechnical Specifications (Quick Reference)\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 10px 0; border: 1px solid #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #efc41a; color: #000000;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eFitting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eEnd Cap (Pipe Termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eCPVC (Chlorinated Polyvinyl Chloride)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e93°C (200°F) continuous service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eSDR-11 (PN 15 \/ 15 kg\/cm² at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eSocket (Solvent Weld)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eASTM D2846, NSF certified for potable water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRecommended Applications\u003c\/h3\u003e\n\u003cul style=\"line-height: 1.9;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDead-End Branches:\u003c\/strong\u003e Sealing unused tee or manifold outlets for future expansion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Testing:\u003c\/strong\u003e Temporarily capping pipes during pressure testing before final connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhased Construction:\u003c\/strong\u003e Closing off pipe stubs for future bathroom or kitchen additions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRenovation Projects:\u003c\/strong\u003e Sealing abandoned pipe sections when rerouting plumbing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManifold Systems:\u003c\/strong\u003e Capping unused outlets on distribution manifolds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemporary Terminations:\u003c\/strong\u003e Closing pipes during staged installation or repairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fcefb9; padding: 15px; border-left: 4px solid #026202; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003col style=\"margin-bottom: 0; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Preparation:\u003c\/strong\u003e Cut pipe squarely; deburr and chamfer pipe end at 10-15° angle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry Fit Check:\u003c\/strong\u003e Insert pipe into end cap socket to verify proper fit (pipe should insert 2\/3 of socket depth)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Cleaning:\u003c\/strong\u003e Clean pipe end and cap socket interior with CPVC cleaner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolvent Cement Application:\u003c\/strong\u003e Apply Ashirvad CPVC solvent cement evenly to both surfaces; insert pipe with quarter turn and hold for 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCuring \u0026amp; Testing:\u003c\/strong\u003e Allow 24 hours curing before pressure testing; verify no leaks at cap joint\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003e1) Can I remove an end cap later if I need to extend the pipe?\u003c\/h3\u003e\n\u003cp\u003eNo, \u003cstrong\u003esolvent-welded end caps create permanent joints\u003c\/strong\u003e that cannot be disassembled. To extend a capped pipe, you must \u003cstrong\u003ecut off the end cap and a short section of pipe\u003c\/strong\u003e, then install a coupler or fitting to continue the line. For temporary closures that may need future access, consider using a \u003cstrong\u003ethreaded plug with a threaded adapter\u003c\/strong\u003e instead.\u003c\/p\u003e\n\u003ch3\u003e2) What's the difference between an end cap and a plug?\u003c\/h3\u003e\n\u003cp\u003eAn \u003cstrong\u003eend cap is a socket fitting\u003c\/strong\u003e that slides over the outside of a pipe and is \u003cstrong\u003esolvent-welded in place\u003c\/strong\u003e. A \u003cstrong\u003eplug is a threaded fitting\u003c\/strong\u003e that screws into a female threaded adapter and can be \u003cstrong\u003eremoved and reinstalled\u003c\/strong\u003e. Use end caps for \u003cstrong\u003epermanent terminations\u003c\/strong\u003e and plugs for \u003cstrong\u003eaccess points or temporary closures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e3) Can I use an end cap for pressure testing a new installation?\u003c\/h3\u003e\n\u003cp\u003eYes, end caps are \u003cstrong\u003eideal for pressure testing\u003c\/strong\u003e new CPVC installations. Install end caps on all open pipe ends, allow proper curing time (24 hours), then pressurize the system to \u003cstrong\u003e1.5x working pressure for 30 minutes\u003c\/strong\u003e. The caps will hold full system pressure without leaking when properly installed.\u003c\/p\u003e\n\u003cp\u003e4) What sizes are available in CPVC end caps?\u003c\/p\u003e\n\u003cp\u003eAshirvad Flowguard Plus end caps are available in \u003cstrong\u003estandard sizes including 15mm (1\/2\"), 20mm (3\/4\"), 25mm (1\"), 32mm (1-1\/4\"), and larger diameters\u003c\/strong\u003e. Always match the end cap size to your pipe diameter for proper fit and sealing.\u003c\/p\u003e\n\u003ch3\u003e5) Do I need to use solvent cement on end caps?\u003c\/h3\u003e\n\u003cp\u003eYes, \u003cstrong\u003ealways use CPVC solvent cement\u003c\/strong\u003e when installing end caps. The cement creates a \u003cstrong\u003emolecular fusion between the cap and pipe\u003c\/strong\u003e, forming a permanent, pressure-tight seal. Never install end caps dry or with just primer, as this will result in leaks under pressure.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy from HomeRun?\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fcefb9; border-left: 4px solid #EFC41A; padding: 15px; border-radius: 5px; margin: 15px 0;\"\u003e\n\u003cul style=\"margin: 0; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuthentic Ashirvad Hardware:\u003c\/strong\u003e Verified genuine products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Fitting Range:\u003c\/strong\u003e All termination and closure fittings for system completion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBangalore Fulfilment:\u003c\/strong\u003e Quick local availability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eReturns \u0026amp; Exchange Policy\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eReturn within 72 hours of delivery for:\n\u003cul\u003e\n\u003cli\u003eDamaged or defective product\u003c\/li\u003e\n\u003cli\u003eWrong or missing item\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct cannot be returned once installed or used\u003c\/li\u003e\n\u003cli\u003eRefer to Refund Policy for complete details\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BuildHome","offers":[{"title":"1\/2\"","offer_id":61844406927730,"sku":"PIP-CPVC-AVG-FGP-END-15","price":11.0,"currency_code":"INR","in_stock":true},{"title":"3\/4''","offer_id":61844406960498,"sku":"PIP-CPVC-AVG-FGP-END-20","price":13.0,"currency_code":"INR","in_stock":true},{"title":"1''","offer_id":61844406993266,"sku":"PIP-CPVC-AVG-FGP-END-25","price":22.0,"currency_code":"INR","in_stock":true},{"title":"1 ¼\"","offer_id":61844407026034,"sku":"PIP-CPVC-AVG-FGP-END-32","price":45.0,"currency_code":"INR","in_stock":true},{"title":"1 ½\"","offer_id":61844407058802,"sku":"PIP-CPVC-AVG-FGP-END-40","price":64.0,"currency_code":"INR","in_stock":true},{"title":"2''","offer_id":61844407091570,"sku":"PIP-CPVC-AVG-FGP-END-50","price":135.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/0405\/1058\/files\/Ashirvad_CPVC_Fitting_End-cap.png?v=1778501831","url":"https:\/\/buildhome.shop\/products\/ashirvad-flowguard-plus-end-cap","provider":"Buildhome","version":"1.0","type":"link"}